FZRN1225-12D 12kV Indoor High-Voltage AC Vacuum Load Switch-Fuse Combination Unit (Intelligent)

+8613806536768
Contact Now
Detail

3.jpg

Utilization of Environmental Conditions:

Ambient Temperature: Not higher than +40 °C, not lower than -15 °C.

Altitude: Not exceeding 1000 m.

Relative Humidity: Daily average not exceeding 95%; Monthly average not exceeding 90%.

Seismic Intensity: Not exceeding degree 10.

Installation Site: Free from fire hazards, explosion risks, heavy pollution, chemical corrosion, and severe vibrations.


Outline and Installation Dimensions



Frequently asked questions

1. Which series should I choose for my application?
ZN85 for general indoor medium-voltage duty, VSG-12 for indoor switchgear with withdrawable configuration, VF2-12 where a permanent-magnet actuator is preferred for lower maintenance, and ZW32 for pole-mounted or outdoor installations (including the 24 kV outdoor version). The deciding factor is the installation type, not the voltage alone.

2. What is the difference between fixed and withdrawable types?
Withdrawable breakers can be racked out for maintenance without opening the cable compartment, which shortens downtime. Fixed types are simpler and cheaper but require the panel to be isolated for breaker maintenance. The choice drives total cost of ownership more than purchase price.

3. Which ratings are available?
The range covers 12 kV, 24 kV and 40.5 kV classes with several current and short-circuit combinations per class. Because a "25 kA at 12 kV" rating is not the same statement as "25 kA at 24 kV", the exact rating must be fixed per voltage class in the technical agreement.

4. What operating mechanism do you offer?
Spring-charged stored-energy mechanisms as standard, with permanent-magnet actuators on the VF2-12 series. Both are available with manual charging and with motor charging for remote operation.

5. Does the breaker include interlocks?
Interlocks are a function of the panel, not of the breaker alone. When supplied as part of a switchgear assembly, the five safety interlocks are included and tested; when supplied as a loose breaker, the interlocking must be designed into the panel.

6. Which standard governs testing?
IEC 62271-100 for circuit breakers, with IEC 62271-1 for general requirements. Routine tests are performed on every unit; type-test reports are provided for the design family.

7. How is the vacuum interrupter life declared?
Electrical life and mechanical life are declared separately and are not interchangeable: mechanical life counts mechanism operations, while short-circuit interruptions are governed by the rated short-circuit breaking capacity. Both values are stated in the technical data sheet.

8. What about the load-switch fuse combination (FZRN)?
The FZRN1225-12D combines a vacuum load-break switch with high-voltage fuses for transformer protection, typically on the incoming circuit of a compact substation. It is a different device from a circuit breaker and is selected where fault levels allow fuse protection.